Condor Technology

GLP Heater

ELECTICAL DIRECT HEATER – GENERAL PURPOSE MODEL GLP- *A

Description

Application

Space-heaters for Non-hazardous locations are designed for

  • Freeze protection
  • Anti-condensation
  • Temperature maintenance

Features and Advantages

  • Self-limiting heating elements

  • Small dimensions

  • No moving parts, no maintenance required, therefore long lifetime

  • Can be used for 110 / 240 VAC/DC

Remarks

  • All Cameo Space-heaters are designed around self-limiting heating elements. These semiconductor elements are saving power consumption.

  • Our Cameo Space-heaters are designed to heat the air inside an enclosure and indirectly the installed equipment. If properly selected for freeze protection, no thermostat will be needed.

  • When required in other applications, e.g. analyzers, it is normal practice to use our Space-Heaters in combination with our Fix-Therm96 thermostats (range from 10 °C up to 135 °C).

  • Do not cover the fins to guarantee free convection.

Range

GLP-1A – T3 ca. 115°C Surface temperature 100-10 Watt

GLP-2A – T4 ca. 105°C Surface temperature 100-10 Watt

GLP-3A – T4 ca. 90°C Surface temperature 100-10 Watt

GLP-4A – T4 ca. 70°C Surface temperature 100-10 Watt

GLP-0AHP – T3
(High power model) ca. 130°C Surface temperature 200-20 Watt

* these temperatures are measured at 20°C ambient temperature.

Technical data

Power consumption 100-10 Watt or 200-20 Watt

Electrical cable 3 x 1 sqmm

Material cable non-braided silicone cable

Standard length ca. 1 mtr., other lengths optional

Other lengths to be specified

Weight Aluminium heater ca. 350 g., 316 Stainless Steel 480 g.

Overall dimensions 78 x 30 x 34 mm (LxWxH)

Material black anodized aluminium (A) or 316 stainless steel (S)

Voltage AC/DC 110/240